Multiparameter Water Quality Sonde
SS308-01-N01
Industrial Ion Transmitter
Product Highlights
● Automatic temperature compensation.
● Configurable communication address and baud rate.
● Two-point electrode calibration.
● Upper and lower 3/4-inch threads for installation.
● Optional OLED display.
● Configurable communication address and baud rate.
● Two-point electrode calibration.
● Upper and lower 3/4-inch threads for installation.
● Optional OLED display.
Product Overview
The SpeSense SS308-01-N01 Industrial Ion Transmitter is designed for continuous monitoring of the specified ionic parameter in industrial and environmental water systems. Its ion measurement configuration supports concentration monitoring for water treatment, process supervision and environmental assessment. RS485 communication enables integration with compatible PLCs, industrial controllers and Modbus-based water quality monitoring networks. The target ion, electrode type and measuring range should be specified according to the selected SS308-01 configuration and its product datasheet.
| Item | Specification |
| Model | SS308-01-N01 |
| Power supply / consumption | DC 10–30 V / 0.6 W |
| Interface / protocol | RS485 / Modbus-RTU |
| Range / resolution | 0–100.00 mg/L / 0.01 mg/L: all ion options except chloride0–1000.0 mg/L / 0.1 mg/L: sodium, magnesium and calcium only0–3500.0 mg/L / 0.1 mg/L: chloride only |
| Ion measurement error | 5% FS |
| Repeatability error | ±1 mg/L |
| Response time | <60 s |
| Transmitter environment | −20 to +80 °C; 0–95% RH, non-condensing |
| Electrode operating temperature | 0–50 °C |
| Electrode pressure resistance | 0.2 MPa |
| Electrode cable | 5 m standard; 10 m, 15 m or 20 m customizable |
| Electrode service life | 3–6 months |
| Housing dimensions | 117 × 87 × 43 mm maximum |
| Electrode dimensions / thread | 212 mm overall length; Ø30 mm body; NPT 3/4 at both ends |
| Display | Without OLED or with optional OLED |