Liquid Level Sensor
SS403-05
Intelligent Electromagnetic Flowmeter
Product Highlights
• Cold and heat metering function.
• Dual-frequency excitation for good zero-point stability.
• Self-diagnosis and intelligent operation.
• Built-in reference electrode; no grounding ring required.
• Forward and reverse flow measurement with low-flow measurement capability.
• Dual-frequency excitation for good zero-point stability.
• Self-diagnosis and intelligent operation.
• Built-in reference electrode; no grounding ring required.
• Forward and reverse flow measurement with low-flow measurement capability.
Product Overview
The SpeSense SS403-05 Intelligent Electromagnetic Flow Meter is designed for volumetric flow measurement of conductive liquids and slurries in closed pipelines. Its electromagnetic measurement principle supports bidirectional flow monitoring, while dual-frequency excitation and built-in reference electrode technology help maintain stable zero-point measurement. With configurable 4–20 mA and pulse outputs, RS485 or Modbus communication, and optional HART support, the flow meter is suitable for water supply, wastewater treatment, chemical processing, food production and other industrial fluid measurement applications.
| Parameter | Specification | Parameter | Specification |
| Measurement / Maximum flow rate | 15 m/s | Measurement / Accuracy (source wording) | ±0.2% of measured value + 0.3 m/s |
| Process / Nominal diameter | 10-3000 mm | Process / Nominal pressure | 0.6 MPa, 1.0 MPa, 1.6 MPa, 4.0 MPa or other options |
| Output / Output signal | 4-20 mA / pulse | Communication / Serial interface | RS485; Modbus communication (non-standard) |
| Communication / HART | Optional HART communication protocol | Protection / Integrated type | IP65 |
| Protection / Split type | IP67 or IP68 (optional) | Power / Supply | 86-220 V AC or 24 V DC (optional) |
| Display / Interface | Up to 8-digit LCD display; real-time clock | Display / Unit | Optional m³ or L display unit |
| Electrode / Standard material | Stainless steel 316L | Electrode / Optional materials | Hc, Hb, Ti, Ta, Pt or other customized materials |
| Lining / Material | Ne, FEP, PTFE or polyurethane optional | Housing / Material | Carbon steel; SS304 customization available |
| Medium / Temperature | -20 to 80 °C; up to 180 °C according to requirements | Environment / Ambient temperature | -20 to 60 °C |
| Environment / Humidity | <85% RH, non-condensing | Compliance / CE basis | LVD 2006/95/EC and EMC 2004/108/EC |
| Compliance / EMC and safety | EN 61326-1:2006; EN 61010-1:2001 |